Precautions for operation with fixed torque electric wrench
Mar 01, 2020
Matters needing attention in the operation of fixed torque electric wrench
1.The size of the bolt diameter has a certain effect on the control accuracy.The same type of bolt connection should be used to calibrate the torque value during construction,and it should be checked and calibrated after a period of use.
2.The machine should be turned on and idle for 3-5 minutes before work.If the motor is found to have large sparks,abnormal sound,and unstable torque during operation,it should be immediately stopped and checked,and do not work with illness.
3.Periodically clean and replace the grease.Generally,after working 5000 times,it should be cleaned and oiled once to prolong the service life.
4.The power switch,carbon brush,and fuse on the controller are all wearing parts,which are easy to cause failures,and should be checked frequently and replaced in time.
5.If the screw on the tool is loose during use,it should be tightened in time.